Справочник Пользователя для ASUS E3746

Скачать
Страница из 196
ROG Striker II Extreme / Striker II NSE
4-35
CPU FAN, CHA _FAN1/2/3, PWR FAN, OPT1/2/3 FAN Speed
PWR FAN, OPT1/2/3 FAN Speed
OPT1/2/3 FAN Speed
The onboard hardware monitor automatically detects and displays the CPU 
fan, chassis fan, power fan, and optional fan speed in rotations per minute
power fan, and optional fan speed in rotations per minute
optional fan speed in rotations per minute 
(RPM). If any of the fans is not connected to the motherboard, the field shows 
0. These items are not user-configurable.
Fan Speed Control
OPT1/2/3 Cable Overheat Protection [90]
Allows you to set the temperature over which the system automatically shuts 
down when any of the thermal sensor cables connected to the motherboard 
detects device overheat to protect the device from damage.  
Configuration optitons: [Disabled] [50] [60] [70] [80] [90]
Fan Speed Monitor
 
Select Menu
Item Specific Help
Phoenix-AwardBIOS CMOS Setup Utility
                                    Power
Fan Speed Monitor
 
CPU Fan Speed 
 
4411 RPM 
 
CHA_FAN1 Speed 
 
   0 RPM
 
CHA_FAN2 Speed 
 
   0 RPM
 
CHA_FAN3 Speed 
 
   0 RPM
 
PWR FAN Speed 
 
   0 RPM
 
OPT1 FAN Speed 
 
   0 RPM 
 
OPT2 FAN Speed 
 
   0 RPM
 
OPT3 FAN Speed 
 
   0 RPM 
 
 
Select Menu
Item Specific Help
Select Fan Control 
mode.
Phoenix-AwardBIOS CMOS Setup Utility
                                    Power
F1:Help      ↑↓ : Select Item 
 -/+: Change Value   
  F5: Setup Defaults 
ESC: Exit    →←: Select Menu 
 Enter: Select SubMenu      F10: Save and Exit
Fan Speed Control
 
CPU FAN Control 
 
  [Duty Cycle Mode] 
 
CPU FAN Duty Cycle 
 
  [100%] 
 
CHASSIS FAN Control 
 
  [Duty Cycle Mode] 
 
CHASSIS FAN Duty Cycle  
  [100%]
x  CHASSIS FAN Q-Fan Sense     CPU Temperature
 
OPT FAN1 Control 
 
  [Duty Cycle Mode]
 
OPT FAN1 Duty Cycle 
 
  [100%]
x  OPT FAN1 Target Temperature  40ºC/104ºF
 
OPT FAN2 Control 
 
  [Duty Cycle Mode]
 
OPT FAN2 Duty Cycle 
 
  [100%]
x  OPT FAN2 Target Temperature  40ºC/104ºF
 
OPT FAN3 Control 
 
  [Duty Cycle Mode]
 
OPT FAN3 Duty Cycle 
 
  [100%]
x  OPT FAN3 Target Temperature  40ºC/104ºF