II.
Using the onboard RAID DIP switch
RAID Status
DIP Switch
1
2
3
RAID 0 (stripped)
ON
ON
ON
RAID
10 ON
ON
OFF
JBOD
(Large)
ON
OFF
ON
RAID
3
ON
OFF
OFF
Clone
OFF
ON
ON
RAID
5
OFF
ON
OFF
RESERVED
OFF
OFF
ON
Normal (Individual drives)
OFF
OFF
OFF
a.
Select the setting desired using the DIP switch table.
b.
Using the provided eSATA to eSATA cable, connect one end to the
eSATA port on the RAID box and the other end to the eSATA
controller
card.
c.
Press the power switch button for more than 2 seconds. Wait for
power LED status to change from starting to ready.
d.
Press the “Change mode” button for more than 2 seconds. This will
configure the raid volume.
e.
Navigate to the Disk Management utility to configure the drives.
Note: for the system to detect multiple individual drives, the RAID box must be
connected to a port multiplier compatible eSATA host controller. If the RAID box is
NOT connected to a port multiplier compatible eSATA host controller, the system will
only detect one drive and that is the hard drive in slot HD0.
RAID Monitoring LED
RAID Status
LED Indicator
RAID 10
Access
Blue / Flash
Rebuilding
Blue & Red / Flash
RAID 3
Access
Blue / Flash
Rebuilding
Blue & Red / Flash
RAID 5
Access
Blue / Flash
Rebuilding
Blue & Red / Flash
Clone
Access
Blue
/
Flash
Clone
Blue & Red / Flash
JBOD (Large)
Access
Blue / Flash
RAID 0
Access
Blue / Flash