Справочник Пользователя для AMD LX 900@1.5W

Скачать
Страница из 680
236
AMD Geode™ LX Processors Data Book 
GeodeLink™ Memory Controller Register Descriptions
33234H
6.2.2.17 PM Sensitivity Counters (MC_CF_PMCTR)
MSR Address
20000020h
Type
R/W
Reset Value
00000000_00000006h
MC_CF_PMCTR Register Map
63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32
PM1_SENS
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
PM0_SENS
MC_CF_PMCTR Bit Descriptions
Bit
Name
Description
63:32
PM1_SENS
PMode1 Sensitivity Counter. Counter that controls the GLMC’s sensitivity to entering 
PMode1 power down mode. If PMode1 is enabled, PM1_SENS starts counting down 
from its loaded value whenever the GLMC becomes idle. If it times out and the GLMC is 
still idle, the GLMC goes into PMode1. If, however, the GLMC resumes activity before 
time-out, the counter is reset to its loaded value and PMode1 is not entered. (Default = 
0h)
31:0
PM0_SENS
PMode0 Sensitivity Counter. Counter that controls the GLMC’s sensitivity to entering 
PMode0 power down mode. If PMode0 is enabled, PM0_SENS starts counting down 
from its loaded value whenever the GLMC becomes idle. If it times out and the GLMC is 
still idle, the GLMC goes into PMode0. If, however, the GLMC resumes activity before 
time-out, the counter is reset to its loaded value and PMode0 is not entered.   (Default = 
6h, to allow 32-bit bursts to finish).