Справочник Пользователя для AMCC 9590SE-4ME

Скачать
Страница из 93
Chapter 2. CLI Syntax Reference
64
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
Write journaling is disabled, if no BBU is present, and is enabled, if a 
BBU is present. All data flushing from controller cache will be flushed to 
media if a BBU is installed and enabled. Otherwise, data will be flushed 
to disk only.
Incoming FUA (Force Unit Access) host requests will be honored unless 
a BBU is installed and enabled, in which case, they will be ignored.
For additional information, see “Setting the StorSave Profile for a Unit” in the 
3ware Serial ATA RAID Controller User Guide.
Example:
//localhost> /c0/u5 set storsave=protect
Setting Command Storsave Policy for unit /c0/u5 to [protect] ... 
Done.
/c
x
/u
x
 migrate type=
RaidType
 [disk=
p:-p
[group=3|4|5|6] [stripe=
Stripe
] [noscan] [nocache] 
[autoverify] 
This feature only applies to 9000 series controllers. 
This command allows you to change the existing configuration of a unit with 
type=RaidType. You can make three types of changes:
Increase the capacity
Change the RAID level (with the same or increased capacity)
Change the stripe size
The unit that results from the migration is subject to the same rules and 
policies that apply when creating a new unit with  the /cx add command. For 
example, a valid number of disks and parameters must be specified. 
The destination unit must use all source disks and potentially augment the 
number of disks in the disk=p:-p disk list. Unspecified parameters are 
assigned the default values (stripe size of 64K, write cache enabled, 
autoverify disabled, and ignoreECC disabled). Both source name and serial 
number will be carried over to the destination unit.
A special case of this command is when the source unit has a type of RAID1 
and destination unit has a type of single. In this case, the migrate command 
splits both drives into two identical single disks. The disk name will be 
duplicated on the destination units, but the source unit serial number will not 
be carried over to the new unit. The new destination unit will have its own 
serial number.