GE Protimeter Aquant
4. Place the instrument against the surface of the wall, floor or element at the 
chosen point of measurement as shown. Ensure that your forefinger and 
thumb do not extend beyond the top of the black plastic grip band and wrap 
all fingers around the side of the instrument.
Note:
The Aquant should be held at a nominal 25° to the surface so that both 
top edge of the instrument and the sensor bulge are in contact with the 
surface.
5. Read the relative moisture level value from the display and note that 
moisture condition of the material from the color coded 
LED scale.
2 Zero Feature
The zeroing feature enables the user to compensate for the effects of changes in temperature on the 
calibration. It is necessary to zero the Aquant if the following appear on the display when the 
instrument is held in air away from surfaces:
numbers, or
three lines 
“---” and symbols “°C°F REL)))”
are flashing
The recommended best practice is to always zero the Aquant with respect to the environment in which 
it is about to be used, even if the display shows 
“0”. Read the Operation section above for details.
3 Hold Feature
The relative value shown on the display may be held for 3 seconds by pressing 
 while the Aquant is 
being held against a surface. This feature is useful when using the instrument in areas where the 
display cannot be clearly seen.
4 Auto Switch-Off Override Feature
Press and hold 
 for 3 seconds to switch the instrument 
OFF
.
5 User  Set-Up  Options
The Aquant is initially set-up to switch 
OFF automatically after 1 minute and to emit an audible 
beep for readings beyond the yellow zone. The user may change these default settings by entering 
the Set-up mode.
Setup the User Options as follows:
1. With the instrument switched OFF, press and hold the lower button   and switch ON using the 
upper button 
 . The display will show the firmware version number (e.g. 
“4.06”) until both 
buttons are released.