Test Mode Operation
7-4
Modem 3600
For 2-wire operation, Analog Bilateral Loopback is invalid. In 4-wire 
operation, Analog Bilateral Loopback connects the receive line to the 
transmit line through a buffer amplifier. 
Test the local DTE and cable by entering the &T1 command. Enter a test 
message and verify it is echoed on the screen. If it is not returned 
exactly as entered, the terminal equipment or data cable is at fault. 
To determine if the data cable is defective replace it with a properly 
configured cable with electrical continuity. If the cable checks out but 
the problem remains, the DTE is defective.
If all local equipment checks out, proceed to the“Testing the Remote 
Modem” section on page 7-5.
Issue an escape sequence followed by &T1 to exit analog loopback.
Local Analog Loopback with Self Test  &T8
When the modem is offline in command mode, enter the &T8 command 
to put the modem in Self Test Local Analog Loopback (Figur
The modem transmits a test pattern. The test pattern is looped back to 
the receiver and checked for errors. Entering the &T command causes 
the modem to exit Self Test Analog Loopback. The modem responds 
with a three digit value between 0 and 255 representing the number of 
errors during test pattern detection. If errors occur, repeat the test to 
verify the consistency of the problem. 
Figure 7-2.  Local Analog with Test Pattern