8-126
C122-E003-02EN
GSWB
CHAPTER 8 CLI Operations
 
• Internal communication error.
Cause: An internal error occurred.
Action: Check the system status, and reenter the command. If the error occurs again, 
collect unit information, configuration definition information, and the 
information in different types of logs, and restart the unit.  Alternatively, 
contact a certified service engineer.
• Input parameter error.
Cause: An invalid IP address, community string, authentication password, or packet 
encryption keyword was specified.
Action: Specify valid IP address, community string, authentication password, and 
packet encryption keyword.
• Input parameter duplicate error.
Cause: A trap notification destination server already registered was specified.
Action: Check the trap notification destination servers already registered.
• Set count over.
Cause: Registration exceeding the maximum 8 units was attempted.
Action: Check the number of registered entries.
• Entry isn’t existed.
Cause: Deletion of an unregistered trap notification destination server was 
attempted.
Action: Check the trap notification destination servers already registered.