FDDI Devices
BRIM-F6 User’s Guide
Page A-9
       
Figure A-6. Dual Homing Topology
Concentrator 3 in Figure A-6 has redundant connections to the main ring 
through either concentrator 1 or 2. The FDDI connection rules only 
permit one active connection, Port B. If a cable failure severs concentrator 
3’s connection to concentrator 2, CFM activates Port A.
A.6
FDDI Devices 
FDDI recognizes four station configurations (SAS, DAS, DAC, and 
SAC). These configurations differ by the mix of FDDI entities within the 
station (see Figure A-7).
All stations must have:
one SMT
at least one MAC
one PMD
one PHY.
Port A
Port A
Port A
Port B
Port B
Port B
Port M
Port M
Port M
Port M
Primary 
Connection
Backup
Connection
3
2
1
BRIM-F Book  Page 9  Monday, January 29, 1996  9:26 AM