Справочник Пользователя для Panduit DPOE12U1XY

Скачать
Страница из 64
PANDUIT® DPoE™ Power Patch Panel User’s Guide 
Issue 2.2 
 
 
Part Number: PN378A 
 
 
 
 
 
  
11
 
 
From 
Network
 
  
Grounding Requirements 
 
  
 
 
 
 
 
Network Connection 
 
5.  If the Element Manager is not being used to 
remotely manage the network of DPoE™ 
Power Patch Panels, skip to Connecting the 
Powered Devices 
below.  Otherwise, using a 
standard patch cord (for example, PANDUIT 
part number UTPCH3 or UTPSP3), connect 
the IN management port on the back of the 
panel to an Ethernet switch. A DHCP Server 
must be on this network (unless the DPoE™ 
Power Patch Panel has been configured for 
Static IP operation). The panel may also be 
directly connect to a PC with the PANDUIT 
Element Manager installed, but this PC must 
be setup as a DHCP Server.” 
 
 
 
6.  If multiple panels are being used in the network, 
the OUT management port from one panel may 
be connected to the IN management port on the 
next panel in a daisy chain fashion, as shown. 
Once all of the connections are made, the EM 
or another Network Manager will be able to 
communicate with all the panels over this daisy 
chain of connections. (See page 29, 
Provisioning the Panel, for more information.) 
 
 
 
Connecting the Powered Devices 
 
7.  Remove 1 inch (25.4 mm) of cable jacket being careful not to damage the conductors.