® DPoE™ Power Patch Panel User’s Guide 
Issue 2.2 
 
 
Part Number: PN378A 
 
 
 
 
 
  
40
 
 
If the network operator were simultaneously configuring multiple ports, the following 
screen would instead appear and any values not overwritten would be left 
unchanged.  
 
 
 
Administration Control - This setting {on/off} allows the network operator to control 
whether each individual port is sourcing PoE power.  If this field is set to off, the port 
acts like any port on a non-powered patch panel rather than a PoE port. This 
enables the network operator to mix non-powered or locally powered devices in the 
same panel as PoE devices. The factory default setting for this field is ON.
 
 
Power Priority - This setting {low, high, critical} indicates whether the importance of 
maintaining PoE power to this port in low-power situations.  This field is used in 
coordination with a higher-level Network Management System (if available). 
 
PD Type - This free-form field allows the network operator to enter information on 
the Powered Device (PD), such as the type of device (IP-phone, camera etc.). 
 
Work Area Location - These free-form fields allows the network operator to enter 
information such as the location where the device is located.   
 
Legacy Detection – This setting {enabled, disabled} allows the network operator to 
specify whether this port is connected to a Cisco legacy PoE device.  If this field is 
set to enabled, the DPoE™ Power Patch Panel port will transmit Cisco-standard 
power rather than the IEEE 802.3af-2003 compliant power. 
 
Export Log 
 
This task, like the Export Panel Information capability, allows the network operator to copy the 
Log Messages from the currently selected port, rack or the entire network of DPoE™ Power 
Patch Panels to an external file.   
 
The
 
Export Log button on the tool bar on the View Panel Screen provides an easy mechanism to 
perform this task.