Справочник Пользователя для Parker Products OEM350X

Скачать
Страница из 58
15
OEM650/OEM650X • INSTALLATION
2
3
4
5
6
7
8
5
10
15
20
25
30
35
40
OEM57-51
P
OEM57-40
S
OEM57-40
P
OEM57-51
S
OEM57-83
S
OEM83-62
*
OEM83-93
*
OEM83-135
*
OEM57-83
P
Power Dissipated
(Watts)
Drive Current
(Amps)
S—Series Configuration
P—Parallel Configuration
*—34 size motors are internally wired in Parallel
Figure 2-11.  OEM650/OEM650X Power Dissipation
Over-Temperature Protection
The OEM650/OEM650X is over-temperature protected. The drive will
shut down if its heatplate temperature exceeds 58°C (136°F). To
measure drive temperature under operating conditions, position a
thermal probe on the left edge of the heatplate, approximately 1.5"
from the top of the drive, as shown in Figure 2-12.
Compumotor
OEM
OEM
s
e
r
Measure heatplate temperature 
on left side, 1.5" from top of drive.
Figure 2-12.  Heatplate Temperature Measurement
To keep the drive cool, and ensure that over-temperature protection
does not unexpectedly shut down the drive, the temperature of the
mounting surface adjacent to the drive should not exceed 55°C
(131°F).