Справочник Пользователя для Varec 8315 Series
101
8300
Troubleshooting
7.3
Maintenance
Field maintenance of the TankGate is simplified by several built-in features. The
modular design of the computer control system, in conjunction with quick-disconnect
connectors, allows for on-site replacement of questionable components.
The following standard procedure can be used for repairing the TankGate:
7.3.0.1
Replacing a defective component or module
•
Turn off main power.
•
Open the enclosure door. Remove the case cover of the TankGate.
•
Replace the defective component or module using the instruction supplied with
the spare part.
•
Replace and tighten the case cover.
•
Turn on power and test with PC and ViewRTU.
•
Close the enclosure door.