Справочник Пользователя для Network Technologies ASI-IP-GTW

Скачать
Страница из 93
ASI-IP-GTW User's Manual 
 
 Page 
66 
 
Table 12. Alarms 
 
 
Alarm 
id 
Alarm Severity 
level 
Description 
100 
No sync 
Critical 
No valid ASI input stream detected. 
101 
ASI bitrate too high 
Critical 
The ASI input bitrate has exceeded the 
configured maximum value. 
121 
Bitrate regulation in 
progress 
Filtered 
The regulation algorithm is estimating the 
incoming bitrate to compensate for the 
difference in PCR clocks on the source 
encoder and the IP receiver. While this 
alarm is active, the output bitrate may be 
tuned beyond the limits of the ASI 
specifications. 
130 
Ethernet link down 
Critical 
No link on Ethernet layer 
131 Output 
buffer 
overflow 
Warning 
The total bitrate of the ASI input streams is 
too high. 
140 
ARP unresolved 
Warning  
IP address is not resolved into physical 
MAC address. 
150 
Sequence error   
Warning 
Analysis of the sequence number of the 
RTP layer indicates that IP frames have 
been lost or that they have been received 
out of order. 
151 
No data received 
Warning 
No data received on Ethernet input for 
stream 
152 FEC 
threshold 
exceeded 
Warning 
The frequency of lost frames is higher than 
the configured value. Threshold values are 
configured per stream. 
153 Input 
buffer 
overflow 
Warning 
The total bitrate of the IP input streams is 
too high.  
154 
Data lost 
Critical 
The data stream received for a channel is 
incomplete, and if running FEC, the FEC 
engine is not able to recover all the lost 
frames. 
155 
No lock 
Critical 
The IP receive channel is not able to find 
an initial bitrate for the data received. 
156 
MIP not present 
Warning 
No MIP frames are received. 
157 
Too low latency for 
FEC 
Warning 
The preferred latency is set lower than the 
latency required by the incoming stream. 
160 SNTP 
server 
unreachable 
Warning 
Unit is not receiving answers from the 
SNTP server. 
161 Too 
high 
temperature 
Warning 
Internal temperature of unit is too high. 
162 
Defective fan 
Warning 
One or both of the fans are not spinning. 
200 
No GPS 1PPS 
reference signal 
Warning 
The 1PPS reference signal is lost. (The 
regulator has however not lost 
synchronization) 
201 
Lost GPS 1PPS 
synchronization 
Critical 
The clock synchronization mechanism has 
been resynchronized due to too large 
phase error.