Справочник Пользователя для National Instruments Ultiboard

Скачать
Страница из 281
Chapter 4
Working with Parts
4-24
ni.com
To control the coordinates for the jumper’s starting and ending points, use 
the following from the Line tab: 
X1—The X coordinate of the jumper’s starting point.
X2—The X coordinate of the jumper’s ending point.
Y1—The Y coordinate of the jumper’s starting point.
Y2—The Y coordinate of the jumper’s ending point.
Units—Units of measurement.
To control the jumper’s wire and pin type, use the following in the Jumper 
tab:
Diameter—Sets the wire’s diameter.
Board Side buttons—Select the side of the board on which the jumper 
appears.
Pin Type box—Choose the type of technology for the jumper pins, 
either Through Hole Technology or Surface Mount Technology.
Units—Units of measurement. 
Working with Test Points
Placing Test Points
Default test point pin settings are defined in the PCB Design tab of the 
Preferences
 
dialog box. The default pad settings are based on the settings 
defined in the Pads/Vias tab of the PCB Properties dialog box. They can 
be manually set to use the annular ring specification or pad diameter 
settings by setting the properties of the pad when the test point has been 
placed on the design. 
Complete the following steps to place a test point: 
1.
Be sure a copper layer is selected. 
2.
Choose Place»Test Point.  
3.
Move the pointer over the design. The pointer now has a test point 
attached. 
4.
Click to drop the test point on the design. 
Test points can be moved, oriented, and aligned like parts. Refer to the 
 section for more information.