Справочник Пользователя для National Instruments Ultiboard

Скачать
Страница из 281
Chapter 3
Setting Up a Design
© National Instruments Corporation
3-19
Net Group Settings 
For net groups, the following Group Settings are available: 
Group Name
Clearance Settings
Trace Width Settings
Trace Length Settings
Routing Layers
Routing Priority
Locked
As well as setting the clearance for a net group, you can set clearances for 
individual nets within that group. You can, for example, set the clearance 
for the net group to 10 mils, and the clearance for two or more nets within 
that group to 5 mils. In this case, if any net from the group comes within 10 
mils of any element that is not in the net group, a DRC error is generated. 
If one of the traces that you set to a 5 mils clearance moves to 5 mils or less 
from one of the other traces with the 5 mils clearance setting, a DRC error 
occurs. 
Note
Set individual trace clearances in the Nets tab of the Spreadsheet View. To do this, 
select the desired trace, and locate the Trace Clearance column. Highlight Use Group 
Settings
 and type in the desired clearance for that trace. You can also edit a trace’s 
clearance from the General tab of its properties dialog box. 
For information on any setting, select it in the Group Settings list. A 
description appears in the field at the bottom of the dialog. You may need 
to make the dialog box larger to view some of the descriptions. Do this by 
dragging the dialog’s lower-right corner. 
Part Group Settings 
For part groups, the following Group Settings are available: 
Group Name
Clearance Settings
Part Spacing Settings
Pin & Gate Swapping Settings