Справочник Пользователя для National Instruments NI 9476

Скачать
Страница из 24
NI 9476 Operating Instructions and Specifications
18
ni.com
Hazardous Locations
U.S. (UL) .......................................... Class I, Division 2, 
Groups A, B, C, D, T4;
Class I, Zone 2,
AEx nC IIC T4
Canada (C-UL) ................................. Class I, Division 2, 
Groups A, B, C, D, T4;
Class I, Zone 2, 
Ex nC IIC T4
Europe (DEMKO)............................. EEx nC IIC T4
Environmental
National Instruments C Series modules are intended for indoor use 
only but may be used outdoors if installed in a suitable enclosure. 
Refer to the manual for the chassis you are using for more 
information about meeting these specifications.
Operating temperature
(IEC 60068-2-1, IEC 60068-2-2) ..... –40 to 70 °C 
Storage temperature
(IEC 60068-2-1, IEC 60068-2-2) ..... –40 to 85 °C
Ingress protection.............................. IP 40