Chapter 4
Connecting Signals
© National Instruments Corporation
4-53
Mode 1 Output Timing
Figure 4-39 details the timing specifications for an output transfer in
Mode 1.
Figure 4-39. Mode 1 Output Timing
Name
Description
Minimum
Maximum
T1
WR* = 0 to INTR = 0
250
T2
WR* = 1 to Output
200
T3
WR* = 1 to OBF* = 0
150
T4
ACK* = 0 to OBF* = 1
150
T5
ACK* Pulse Width
100
T6
ACK* = 1 to INTR = 1
150
All timing values are in nanoseconds.
WR*
OBF*
INTR
ACK*
DATA
T1
T2
T3
T4
T5
T6