Справочник Пользователя для NEC NDA-30115-001
NDA-30115 Revision 1.0
Page 63
Property Management System - Communication Interface
Message Formats
Room Move/Swap/Copy (Model 60)
This message group is used exclusively by the Model 60 version. The Function
Codes are:
Codes are:
•
20-1 -- Room Move
•
20-2 -- Room Swap
•
20-5 -- Room Copy
Room Move leaves the second extension’s maid status unchanged, cancels the
second extension’s Room Cut-Off and sets all other data to that of the first
extension. The first extension’s maid status is set to ‘1’, Room Cut-Off is set, Do
Not Disturb and Message Waiting is reset, Wake Up is cancelled, Language is set
to ‘0’ and Guest Name and Group Number are cleared.
second extension’s Room Cut-Off and sets all other data to that of the first
extension. The first extension’s maid status is set to ‘1’, Room Cut-Off is set, Do
Not Disturb and Message Waiting is reset, Wake Up is cancelled, Language is set
to ‘0’ and Guest Name and Group Number are cleared.
Room Swap completely exchanges the data between the first and second
extensions.
extensions.
Room Copy completely copies the data from the first extension to the second
extension. The data for the first extension is unchanged.
extension. The data for the first extension is unchanged.
Figure 4-35 Room Move/Swap/Copy
Message fields are:
•
FC-- There are three functions: (FTC-FC)
•
20-1 -- Room Move
•
20-2 -- Room Swap
•
20-5 -- Room Copy
•
First Extension -- This is the source extension number. If the extension number
is less than six digits, left justify the number and fill the remaining bytes with
space (20H) characters.
is less than six digits, left justify the number and fill the remaining bytes with
space (20H) characters.
•
Second Extension -- This is the destination extension number. If the extension
number is less than six digits, left justify the number and fill the remaining bytes
with space (20H) characters.
number is less than six digits, left justify the number and fill the remaining bytes
with space (20H) characters.
‘2’ ‘0’
‘1’
‘7’
**
First
Second
** Multiple Function Codes use this message. See below.
Extension Extension
0
1
2
3
4
6
8
9
15
21
22
STX
SA
UA
EI
FTC
MSC
FC
6
6
02H ‘1’
‘!’
‘L’
03H xx