Справочник Пользователя для NEC NDA-30115-001
Page 76
NDA-30115 Revision 1.0
Message Formats
Property Management System - Communication Interface
Room Image Set 3
Figure 4-49 Room Image Set 3
The message fields are:
•
FC -- Function Codes that use this message format are: (FTC-FC)
•
17-9 -- Room Image Set 3 (Normal Request from PMS)
•
17-A -- Room Image Set 3 (Normal Answer from NEAX)
•
17-B -- Room Image Set 3 (Recovery Request from PMS)
•
17-C -- Room Image Set 3 (Recovery Answer from NEAX)
•
Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
left justify the number and fill the remaining bytes with space (20H) characters.
•
Vacancy -- Vacancy/Occupancy flag. The possible values are:
•
0 -- Vacant.
•
1 -- Occupied.
•
Status - Message Waiting status. The possible values are:
•
0 -- Message Waiting Lamp is off.
•
1 -- Message Waiting Lamp is on.
•
Code -- Restriction code for this extension. The possible codes are:
•
0 -- Do Not Disturb and Room Cut-Off are cancelled.
•
1 -- Room Cut-Off is set, Do Not Disturb is cancelled.
•
5 -- Do Not Disturb is set, Room Cut-Off is cancelled.
•
6 -- Do Not Disturb and Room Cut-Off are set.
Blank 1
Cleaning Wake Up
Result
Status
Group ID Blank 2
** Multiple Function Codes use this message. See below.
Vacancy
Stay
Reserve
Language
Wake Up
Status
Time
‘1’ ‘7’
‘3’
‘8’
**
Extension
0
1
2
3
4
6
8
9
15
16
STX
SA
UA
EI
FTC
MSC
FC
6
1
1
02H ‘1’
‘!’
‘L’
ETX BCC
1
1
1
1
1
1
17
18
19
20
21
22
Code
23
27
32
38
42
43
4
5
6
4
03H xx