 Chapter 3 — System and site requirements
553-3021-209
Standard 3.00
April 2000
Meridian Administration Tools
The Option 11C Mini supports the Meridian Administration Tools (MAT) 
application. For information about MAT requirements and installing MAT 
for the Option 11C Mini, refer to the MAT User Guides.
Cross-connect terminal requirements
Allow for future expansion and equipment changes at the cross-connect 
terminal.
The cross-connect terminal must have enough space for connecting blocks to 
terminate the following wires:
five 25-pair cables from each Main Chassis
four 25-pair cables from the Chassis Expander
four conductors for the AUX cable from the Main Chassis
one 25-pair cable from each QUA6 PFTU 
wiring from telephone sets and trunks
The BIX cross-connect system is recommended for use with the Option 11C 
Mini system. However, use of this system is not mandatory. You can use 
some other cross-connect systems (for example, the Krone Test Jack Frame 
for the UK and the Reichle Masari cross-connect terminal for Germany).
Only allow authorized personnel to
 
access the Krone Test Jack Frame. Install 
the Krone Test Jack Frame in a locked room or in an environment that 
prevents free access to the equipment. The Krone Test Jack Frame must meet 
this safety requirement to receive approval.
You can find information about the BIX cross-connect system in the 
following documents:
BIX In-Building Cross-Connect System Material Description 
(631-4511-100)
BIX In-Building Cross-Connect System Material Installation and 
Servicing 
(631-4511-200)
Refer to “Chapter 13 — Installing and connecting the cross-connect terminal” 
on page 169 fo
r additional information about the BIX, Krone Test Jack 
Frame, and Reichle Masari cross-connect terminals.