Справочник Пользователя для Nortel Networks 4050

Скачать
Страница из 922
794 Chapter 17 Configuration example
320818-A
 
Configuring SSH
In this example, the assumption is that the Nortel SNAS 4050 public key has 
already been uploaded to the TFTP server (10.20.20.20).
5510-48T(config)# ssh download-auth-key address 10.20.20.20 
key-name sac_key.1.pub
5510-48T(config)# ssh
Configuring the Nortel SNAS 4050 pVIP subnet
5510-48T(config)# nsna nsnas 10.40.40.0/24
Creating port-based VLANs
5510-48T(config)# vlan create 210 type port
5510-48T(config)# vlan create 220 type port
5510-48T(config)# vlan create 230 type port
5510-48T(config)# vlan create 240 type port
Configuring the VoIP VLANs
5510-48T(config)#nsna vlan 240 color voip
Configuring the Red, Yellow, and Green VLANs
5510-48T(config)#nsna vlan 210 color red filter red
5510-48T(config)#nsna vlan 220 color yellow filter yellow 
yellow-subnet 10.120.120.0/24
5510-48T(config)#nsna vlan 230 color green filter green