Справочник Пользователя для Delta Electronics none
Chapter 7 Servo Parameters|ASDA-AB Series
Revision March 2008, Doc. Name: 2007PDD23000011
7-9
7.2.2 Parameters List by Function
Monitor and General Use
Control
Mode
Parameter Name
Function
Default Unit
Pt Pr S T
Related
Section of
User
Manual
P0-00★
VER Firmware
Version
Factory
setting
N/A { {` { {
---
P0-01★
ALE
Drive Fault Code
N/A
N/A { { { {
10.1
P0-02 STS
Drive
Status
00 N/A { { { {
4.3.5
P0-03
MON Analog Monitor Output
01
N/A { { { {
4.3.5
P0-04
CM1 Status Monitor 1
0
N/A { {
{
{
4.3.5
P0-05
CM2 Status Monitor 2
0
N/A { {
{
{
4.3.5
P0-06
CM3 Status Monitor 3
0
N/A { {
{
{
4.3.5
P0-07
CM4 Status Monitor 4
0
N/A { {
{
{
4.3.5
P0-08
CM5 Status Monitor 5
0
N/A { {
{
{
4.3.5
P0-09
MAP0 Block Data Read / Write Register 0
407H
N/A { {
{
{
---
P0-10
MAP1 Block Data Read / Write Register 1
10FH
N/A { {
{
{
---
P0-11
MAP2 Block Data Read / Write Register 2
110H
N/A { {
{
{
---
P0-12
MAP3 Block Data Read / Write Register 3
224H
N/A { {
{
{
---
P0-13
MAP4 Block Data Read / Write Register 4
111H
N/A { {
{
{
---
P0-14
MAP5 Block Data Read / Write Register 5
112H
N/A { {
{
{
---
P0-15
MAP6 Block Data Read / Write Register 6
225H
N/A { {
{
{
---
P0-16
MAP7 Block Data Read / Write Register 7
109H
N/A { {
{
{
---
P0-17
SVSTS Servo Output Status Display
N/A
N/A { { { {
---
P1-03
AOUT Pulse Output Polarity Setting
0
N/A { {
{
{
3.3.3
P1-04 MON1
Analog Monitor Output Proportion 1
(CH1)
(CH1)
100 %
{
{
{
{
6.4.4
P1-05 MON2
Analog Monitor Output Proportion 2
(CH2)
(CH2)
100 %
{
{
{
{
6.4.4
Explanation of symbols (marked after parameter)
(★) Read-only
register.
(▲)
Parameter cannot be set when Servo On (when the servo drive is enabled).
(●)
Parameter is effective only after the servo drive is restarted (after switching power off and on).
(■)
Parameter setting values are not retained when power is off.