Справочник Пользователя для Delta Electronics none

Скачать
Страница из 355
 Chapter 7 Servo Parameters|ASDA-AB Series 
Revision March 2008, Doc. Name: 2007PDD23000011 
 
7-9
 
7.2.2  Parameters List by Function 
Monitor and General Use 
Control 
Mode 
Parameter  Name 
Function 
Default Unit
Pt  Pr  S  T 
Related 
Section of 
User 
Manual 
P0-00★ 
VER Firmware 
Version 
Factory 
setting
N/A {  {`  {  { 
--- 
P0-01★ 
ALE 
Drive Fault Code 
N/A 
N/A {  {  {  { 
10.1 
P0-02 STS 
Drive 
Status 
00 N/A {  {  {  { 
4.3.5 
P0-03 
MON  Analog Monitor Output 
01 
N/A {  {  {  { 
4.3.5 
P0-04 
CM1  Status Monitor 1 
N/A {  {
 
{
  { 
4.3.5 
P0-05 
CM2  Status Monitor 2 
N/A {  {
 
{
  { 
4.3.5 
P0-06 
CM3  Status Monitor 3 
N/A {  {
 
{
  { 
4.3.5 
P0-07 
CM4  Status Monitor 4 
N/A {  {
 
{
  { 
4.3.5 
P0-08 
CM5  Status Monitor 5 
N/A {  {
 
{
  { 
4.3.5 
P0-09 
MAP0  Block Data Read / Write Register 0
407H 
N/A {  {
 
{
  { 
--- 
P0-10 
MAP1  Block Data Read / Write Register 1
10FH 
N/A {  {
 
{
  { 
--- 
P0-11 
MAP2  Block Data Read / Write Register 2
110H 
N/A {  {
 
{
  { 
--- 
P0-12 
MAP3  Block Data Read / Write Register 3
224H 
N/A {  {
 
{
  { 
--- 
P0-13 
MAP4  Block Data Read / Write Register 4
111H 
N/A {  {
 
{
  { 
--- 
P0-14 
MAP5  Block Data Read / Write Register 5
112H 
N/A {  {
 
{
  { 
--- 
P0-15 
MAP6  Block Data Read / Write Register 6
225H 
N/A {  {
 
{
  { 
--- 
P0-16 
MAP7  Block Data Read / Write Register 7
109H 
N/A {  {
 
{
  { 
--- 
P0-17 
SVSTS  Servo Output Status Display 
N/A 
N/A {  {  {  { 
--- 
P1-03 
AOUT  Pulse Output Polarity Setting 
N/A {  {
 
{
  { 
3.3.3 
P1-04 MON1 
Analog Monitor Output Proportion 1 
(CH1) 
100 % 
{
  {
 
{
  { 
6.4.4 
P1-05 MON2 
Analog Monitor Output Proportion 2 
(CH2) 
100 % 
{
  {
 
{
  { 
6.4.4 
 
 
 
 
 
 
 
 
Explanation of symbols (marked after parameter) 
(★) Read-only 
register. 
(▲) 
Parameter cannot be set when Servo On (when the servo drive is enabled). 
(●) 
Parameter is effective only after the servo drive is restarted (after switching power off and on). 
(■) 
Parameter setting values are not retained when power is off.