Revision March 2008, Doc. Name: 2007PDD23000011 
 
9-1
 
Chapter 9  Maintenance and Inspection 
Delta AC servo drives are based on solid state electronics technology. Preventive maintenance is required to 
operate this AC servo drives in its optimal condition, and to ensure a long life. It is recommended to perform 
a periodic maintenance and inspection of the AC servo drive by a qualified technician. Before any 
maintenance and inspection, always turn off the AC input power to the unit. 
 
 
¾
  Be sure to disconnect AC power and ensure that the internal capacitors have fully discharged before performing 
the maintenance and inspection! 
 
9.1 Basic 
Inspection 
After power is in connected to the AC servo drive, the charge LED will be lit which indicates that the AC 
servo drive is ready. 
Item 
Content 
General Inspection 
z
  Periodically inspect the screws of the servo drive, motor shaft, terminal block and 
the connection to mechanical system. Tighten screws as necessary as they may 
loosen due to vibration and varying temperatures.  
z
  Ensure that oil, water, metallic particles or any foreign objects do not fall inside 
the servo drive, motor, control panel or ventilation slots and holes. As these will 
cause damage. 
z
  Ensure the correct installation and the control panel. It should be free from 
airborne dust, harmful gases or liquids. 
z
  Ensure that all wiring instructions and recommendations are followed; otherwise 
damage to the drive and or motor may result. 
Inspection before 
operation 
(Control power is not 
applied) 
z
  Inspect the servo drive and servo motor to insure they were not damaged. 
z
  To avoid an electric shock, be sure to connect the ground terminal of servo drive 
to the ground terminal of control panel.  
z
  Before making any connection, wait 10 minutes for capacitors to discharge after 
the power is disconnected, alternatively, use an appropriate discharge device to 
discharge. 
z
  Ensure that all wiring terminals are correctly insulated. 
z
  Ensure that all wiring is correct or damage and or malfunction may result. 
z
  Visually check to ensure that there are not any unused screws, metal strips, or 
any conductive or inflammable materials inside the drive. 
z
  Never put inflammable objects on servo drive or close to the external 
regenerative resistor. 
z
  Make sure control switch is OFF. 
z
  If the electromagnetic brake is being used, ensure that it is correctly wired. 
z
  If required, use an appropriate electrical filter to eliminate noise to the servo drive.
z
  Ensure that the external applied voltage to the drive is correct and matched to the 
controller.