Справочник Пользователя для Delta Electronics none

Скачать
Страница из 355
Chapter 10  Troubleshooting|ASDA-AB Series
 
10-8  
 
Revision March 2008, Doc. Name: 2007PDD23000011
 
10.3 Clearing Faults 
Display 
Fault Name 
Clearing Method 
 
Overcurrent 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
 
Overvoltage 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
 
Undervoltage 
This fault message can be removed automatically 
after the voltage has returned within its 
specification.  
 
Z Pulse shift 
Restart the servo drive.  
 
Regeneration error 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
 
Overload 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
 
Overspeed 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
 
Abnormal pulse control 
command 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
 
Excessive deviation 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
 
Watch dog execution time 
out 
This fault message cannot be cleared. 
 
Encoder error 
This fault message can be removed by restarting 
the servo drive.  
 
Adjustment error 
This fault message can be removed after the 
wiring of CN1 connector (I/O signal connector) is 
removed and auto adjustment function is 
executed. 
 
Emergency stop activated 
This fault message can be removed automatically 
by turning off EMGS (DI signal). 
 
Reverse limit switch error 
Turn ARST (DI signal) ON to clear the fault. This 
fault message can be removed when the servo 
drive is Off (Servo Off) 
 
Forward limit switch error 
Turn ARST (DI signal) ON to clear the fault. This 
fault message can be removed when the servo 
drive is Off (Servo Off) 
 
IGBT temperature error 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
 
Memory error 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
 
DSP communication error 
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive. 
 
Serial communication error 
Turn ARST (DI signal) ON to clear the fault. This 
fault message can also be removed automatically 
after the communication is normal.  
 
Serial communication time 
out  
Turn ARST (DI signal) ON to clear the fault or 
restart the servo drive.