Справочник Пользователя для Delta Electronics none

Скачать
Страница из 355
Chapter 12  Application Examples|ASDA-AB Series
 
12-14  
 
Revision March 2008, Doc. Name: 2007PDD23000011
 
12.6  Feed Step Control 
 
„
 
Relevant Parameters Description 
Parameter 
Communication 
Address 
Parameter Description 
P1-01 
0101H 
Control Mode and Output Direction 
001: Forward torque in Pr mode 
101: Reverse torque in Pr mode 
P1-12 
010CH 
Torque Limit Setting 
Torque decrease value is represented by a percentage of rated 
torque. 
P1-33 
0121H 
Position Control Mode (Pr) 
2: Forward operation search feed step 
3: Reverse operation search feed step 
4: Short-pass search feed step 
P1-34 0122H 
Acceleration 
Time 
1st to 3rd step Acceleration time (When parameter P1-36 is set to 0, 
accel / decel function is disabled, i.e. P1-34, P1-35 is disabled) 
P1-35 0123H 
Deceleration 
Time 
1st to 3rd step Deceleration time (When parameter P1-36 is set to 0, 
accel / decel function is disabled, i.e. P1-34, P1-35 is disabled) 
P1-36 
0124H 
Accel /Decel S-curve 
When parameter P1-36 is set to 0, accel / decel function is disabled, 
i.e. P1-34, P1-35 is disabled. 
P1-44 
012CH 
Electronic Gear Ratio (1st Numerator) (N1) 
If the electronic gear deceleration ratio is 1/75, set numerator to 75 
P1-45 
012DH 
Electronic Gear Ratio (Denominator) 
P1-47 012FH 
Homing 
Mode 
202: When (MD1, MD0)=(OFF, ON), Forward Homing 
203: When (MD1, MD0)=(OFF, ON), Reverse Homing