Справочник Пользователя для Delta Electronics none

Скачать
Страница из 355
Chapter 4  Display and Operation|ASDA-AB Series
 
4-4  
 
Revision March 2008, Doc. Name: 2007PDD23000011
 
Display Message 
Description 
 
Negative value display. When the parameter setting is greater 
than four digits (for the setting value within the range of less than 
five decimal places), after the display value is set, continuously 
press SHIFT key for many times and then the lit decimal points 
are used to indicate a negative value. 
 
Negative value display. When the parameter setting is less than 
five digits (for the setting value within the range of five decimal 
places), after the display value is set, continuously press SHIFT 
key for many times and then the negative sign will show up to 
indicate a negative value. 
4.3.5  Monitor Setting Display 
When the AC servo drive is applied to power, the LCD display will show the monitor function codes for 
approximately one second and then enter into the monitor mode. In monitor mode, in order to change 
the monitor status, the users can press UP or DOWN arrow key or change parameter P0-02 directly to 
specify the monitor status. When the power is applied, the monitor status depends on the setting value 
of P0-02. For example, if the setting value of P0-02 is 2 when the power is applied, the monitor function 
will be Pulse counts of pulse command, the C.P monitor codes will first display and then the pulse 
number will display after. 
P0-02 
Setting 
Display Message 
Description 
Unit 
 
Motor feedback pulse number (absolute 
value) 
pulse 
 
Motor feedback rotation number  
(absolute value) 
rev 
 
Pulse counts of pulse command 
pulse 
 
Rotation number of pulse command 
rev 
 
Position error counts 
pulse 
 
Input frequency of pulse command 
r/min 
 
Motor speed  
r/min 
 
Speed input command 
Volt 
 
Speed input command 
r/min