Справочник Пользователя для Delta Electronics none

Скачать
Страница из 355
Chapter 4  Display and Operation|ASDA-AB Series 
Revision March 2008, Doc. Name: 2007PDD23000011 
 
 
4-7 
4.4.2  JOG Operation 
After entering parameter mode P4-05, the users can follow the following steps to perform JOG operation. 
(Please also refer to Figure 4.4). 
Step1.  Press the SET key to display the JOG speed. (The default value is 20 r/min). 
Step2.  Press the UP or DOWN arrow keys to increase or decrease the desired JOG speed. (This also 
can be undertaken by using the SHIFT key to move the cursor to the desired unit column (the 
effected number will blink) then changed using the UP and DOWN arrow keys. The example 
display in Figure 4.4 is adjusted as 100 r/min.) 
Step3.  Press the SET key when the desired JOG speed is set. The Servo Drive will display "JOG". 
Step4.  Press the UP or DOWN arrow keys to jog the motor either CCW or CW. The motor will only 
rotate while the arrow key is activated. 
Step5.  To change JOG speed again, press the MODE key. The servo Drive will display "P4 - 05". 
Press the SET key and the JOG speed will displayed again. Refer back to #2 and #3 to change 
speed. 
NOTE
 
1)  JOG operation is effective only when Servo On (when the servo drive is enabled). 
 
Figure 4.4