Справочник Пользователя для Dialogic TX4000 PCI SS7

Скачать
Страница из 48
Installing the TX 4000 board 
 
TX 4000 PCI SS7 Network Interface Board Installation Manual 
The following illustration shows the H.100 termination DIP switch: 
 
S2
OFF
ON
1
2
34
56
7
8
 
Configuring SS7 Monitor mode 
DIP switch S3 controls the SS7 Monitor mode. The DIP switch is located on the front 
of the board, to the right of the T1/E1 trunk connectors. By default, all S3 switches 
are set to the ON position. This setting disables SS7 Monitor mode. When SS7 
Monitor mode is disabled, the TX board is an active participant in the network. 
To enable SS7 Monitor mode, set the S3 switches to the OFF position. In this mode, 
the board becomes a passive listening device that monitors network traffic. For 
information on connecting the monitoring server (with an installed TX board) to the 
network and installing the SS7 Monitor software, refer to the Dialogic® 
NaturalAccess™ SS7 Monitor Developer's Reference Manual and to the Installing 
Dialogic® NaturalAccess™ SS7 Monitor Software 
instructions. 
Note: The switches in DIP switch S3 must be set to either all ON or all OFF. 
The following illustration shows the Monitor mode DIP switch: 
 
S3
OFF
ON
12
3
4
 
18 
 
 
 
 
 
 
 
 
Dialogic Corporation