Справочник Пользователя для Dialogic TX4000 PCI SS7

Скачать
Страница из 48
Verifying the installation   
TX 4000 PCI SS7 Network Interface Board Installation Manual 
Status LEDs 
After the boot code LEDs become green, the status LEDs are active and indicate the 
current board status as described in the following table: 
LED 
number 
Color  Status when illuminated 
D8 
Green  Timer interrupt controlled heartbeat. The LED flickers to show that the timer 
interrupts are operating properly. 
D9 
Green  Idle task controlled heartbeat. The LED flickers to show that the on-board operating 
system is operational. 
D12 
Red 
The board is executing in snapshot mode: the board is resetting or txsnap is 
running. 
D13 
------  Reserved for internal use.  
D18 
Red 
The kernel detected a host communication error. 
D19 
Red 
A memory full condition occurred on the board. 
D20 
Red 
An unexpected exception occurred on the board. 
D21 
Red 
The kernel detected a problem. Use the cpcon utility's log command to view logged 
error information. For information about using cpcon, refer to the Dialogic® TX 
Series SS7 Boards TX Utilities Manual
40 
 
 
 
 
 
 
 
 
Dialogic Corporation