Installing FOM-E1/T1 
Quick Start Guide 
 
Installation of FOM-E1/T1 should be carried out only by an experienced 
technician. If you are familiar with FOM-E1/T1, use this quick start guide to set it 
up for operation.  
This guide describes the standalone version of the modem. 
Perform the installation procedures for both the local and the remote units. 
1. Installing 
FOM-E1/T1 
Configuring FOM-E1/T1 
1.  Open the modem’s case. 
2.  Select the E1/T1 electrical interface (JP2, JP4, JP5, JP6, JP7 and JP8). 
3.  If using E1 unbalanced interface, connect the BNC shield to the chassis ground. 
If you are using balanced E1/T1, leave the shield floating (SW1 and SW2). 
4.  Close the modem’s case. 
Table below provides details on the functions of the internal jumpers and switches, 
and their default settings. 
Jumper/Switch Function 
Possible 
Settings 
Factory 
Setting 
SW3, AIS 
When a major alarm is 
detected, AIS is transmitted 
to either the electrical or 
optical interface. 
ON – Transmit AIS 
OFF – Do not transmit AIS 
ON 
SW2, INPUT Ground 
SW1, OUTPUT Ground  
Controls connection of the 
BNC shield to the chassis 
ground 
CONNECTED – BNC shield is connected 
to the chassis ground  
(for E1 unbalanced) 
FLOATING – BNC shield is disconnected 
from the chassis ground  
(for E1/T1 balanced) 
 
 
 
 
FLOATING 
JP2, JP4, JP5, JP6, JP7, JP8, 
INTERFACE 
Selects the E1/T1 electrical 
interface 
100 ohm BAL T1 – T1 100Ω balanced 
(DB-15 connector) 
120 ohm BAL CEPT – E1 120Ω balanced 
(DB-15 connector) 
75 ohm UNBAL CEPT – E1 75Ω 
unbalanced  
(BNC 
connectors) 
 
 
120 ohm 
BAL CEPT 
Note
For 
FOM-E1/T1
 units with 115 VAC, factory setting is 100
Ω
 BAL T1.