Справочник Пользователя для RAD Data comm E1

Скачать
Страница из 46
FOM-E1/T1 Installation and Operation Manual 
Chapter 1  Introduction 
 
Technical Specifications 
1-5 
1.4 Technical Specifications 
E1/T1 
Interface 
Transmission Rates 
E1: 2.048 Mbps  
T1: 1.544 Mbps  
 
Interface 
User-selectable: 
•  E1: 120Ω balanced or 75Ω unbalanced 
•  T1: 100Ω balanced 
 
Zero Suppression 
E1: HDB3 
T1: B8ZS 
 
Connectors 
Balanced: 15-pin D-type, female 
Unbalanced: two BNC 
Optical 
Interface 
Operating 
Wavelength 
See 
 
Receiver Sensitivity 
For BER 10
-9
•  -38 dBm at 850 nm 
•  -40 dBm at 1310 nm or 1550 nm 
 
Connectors 
ST, SC or FC  
 
Dynamic Range 
28 dB for all types of optical interfaces 
 
Budget (Max) 
20 dB for 850 nm over 62.5/125 
22 dB for 1310 nm over 9/125 
28 dB for 1310 nm or 1550 nm laser over 9/125 
Alarm 
Operation 
Normally Open and Normally Closed, using different pins 
 
Connector 
15-pin, D-type, female 
Indicators 
POWER 
ON – The unit is powered 
 
TEST LOC 
ON – The unit is in local loopback mode 
 
TEST REM 
ON – The unit is in remote loopback mode 
 
ELECTRICAL LOW 
ON – The electrical interface input is below G.703 
electrical levels 
 
ELECTRICAL AIS 
ON – An “All 1s” string is received at the electrical 
interface 
 
OPTICAL ERR 
ON – Bit error rate of the received signal from the optical 
interface is 10
-6
 or worse 
 
OPTICAL AIS 
ON – An “All 1s” string is received at the optical interface