Справочник Пользователя для RAD Data comm E1

Скачать
Страница из 46
FOM-E1/T1 Installation and Operation Manual 
Chapter 5  FOM-E1/T1/R Card Version 
 
Power Supply 
5-3 
DC Supply  
The DC power supply is -48 VDC (-36 to -72 VDC) or 24 VDC (18 to 32 VDC). It 
uses a DC/DC converter module to provide the power required for the cards. 
Power Supply Redundancy 
This special ordering option is equipped with two separate power supplies, 
operating together and sharing the load of the whole card cage. If either of the 
power supplies fails, the other one will continue to supply power to the full card 
cage. 
Two LED indicators show activity of each power supply. They should both light 
when mains power is provided. 
 
It is possible to combine AC and DC power supplies in the same cage. 
 
 
Figure 5-2  ASM-MN-214 Front Panel 
 