Справочник Пользователя для RAD Data comm IPmux-1E

Скачать
Страница из 143
IPmux-1/1E Installation and Operation Manual 
Appendix E  Parameters and Screens 
 
General Configuration 
E-9 
Alarm Traps Mask 
Each of the IPmux-1/1E alarms can activate a trap toward the NMS. It is possible to 
enable/disable the trap operation for each one of the alarms, using the Alarm Trap 
Mask screen.  
 
ALARM TRAPS MASK 
1. Alarm ID <refer to Manual> 
  1 
2. Trap Status 
  
Active 
 
Alarm Active Traps: 
Select item from the menu. 
Use <Esc> key or keys <1> to <2> 
Figure E-12.  Alarm Traps Mask Menu 
Table E-4.  Alarm Traps Mask Parameters 
Parameter Possible 
Values 
Remarks 
Alarm ID 
1, 2, 6, 8, 21, 26, 27 
IPmux-1/1E alarm 
Trap Status 
Active 
Masked 
Generates an alarm 
Does not send an alarm 
Default for all traps: Masked 
Table E-5.  IPmux-1/1E Alarms 
Alarm ID 
Alarm Description 
Trap Sent to NMS 
Loss of Signal (LOS Physical Layer)  
Alarm LOS 
1.3.6.1.4.1.164.6.1.3.0.7 
Loss of Frame (LOF Physical Layer)  
Alarm LOF 
1.3.6.1.4.1.164.6.1.3.0.8 
Alarm Indication Signal Received (AIS 
Line Physical Layer)  
Alarm AIS 
1.3.6.1.4.1.164.6.1.3.0.10 
Remote Defect Indication Received (RDI 
Line Physical Layer)  
Alarm RDI 
1.3.6.1.4.1.164.6.1.3.0.11 
21 
Far End Block Error (FEBE Line Layer)  
Alarm FEBE 
1.3.6.1.4.1.164.6.1.3.0.12 
26 
Local Connectivity Fail 
Local Conn Status Trap 
1.3.6.1.4.1.164.6.1.3.0.13 
27 
Remote Connectivity Fail 
Remote Conn Status Trap 
1.3.6.1.4.1.164.6.1.3.0.14 
 
Main Menu 
         ↓ 