Справочник Пользователя для RAD Data comm IPmux-1E

Скачать
Страница из 143
Chapter 3  Operation 
IPmux-1/1E Installation and Operation Manual 
3-4  Operating Instructions
 
 
Table 3-2.  IPmux-1E (BRI/FXS) System Indicators and Switches (Cont.) 
No. Name 
Type  Function 
ETH LINK 
LED 
On: Line OK 
Off: Link not active 
ETH ACT 
LED 
On: Frame being transferred on line 
Off: No activity 
6 ETH 
100M 
LED 
On: 100 Mbps 
Off: 10 Mbps 
ETH FDX 
LED 
On: Full duplex 
Off: Half duplex 
POWER 
Switch  Turns IPmux-1E power ON and OFF 
3.2 Operating 
Instructions 
Turning IPmux-1/1E On 
Without Control Terminal 
The IPmux-1/1E power switch is located on the back panel, as shown in  
Figure 3-2.  
➤ 
To power up IPmux-1/1E without a Control terminal: 
1.  Turn the power supply switch, located on the rear panel, to ON.  
2.  Check the unit LED indicators, located on the left side of the front panel, and 
the module indicators for proper operation (see Figure 3-1, Figure 3-2, 
Figure 3-3, Figure 3-4, Table 3-1, and Table 3-2)
With Control Terminal 
➤ 
To power up IPmux-1/1E with a Control terminal: 
1.  Make sure all IPmux-1/1E cables and connectors are properly connected. 
2.  Connect IPmux-1/1E to a PC equipped with an ASCII terminal-emulation 
application (for example, Windows 95 Hyper Terminal or Procomm). 
3.  Turn on the control-terminal PC and set its default port parameters to  
19,200 baud, 8 bits/character, 1 stop bit, No Parity. Set the terminal emulator 
to ANSI VT100 emulation (for optimal view of system menus).  
4.  Switch ON the POWER supply switch, located on the rear panel. 
5.  When the initialization and self-test are over, a menu appears displaying 
initialization and self-test results. If the self-test is successful, the RDY LED 
(Figure 3-1 and Figure 3-3) on the left side of the front panel lights. If problems 
are encountered, refer to Chapter 4 for instructions.  