Appendix E  Parameters and Screens 
IPmux-1/1E Installation and Operation Manual 
E-24 Analog 
Configuration 
 
Signaling Profile Configuration 
SIGNALING PROFILE CONFIGURATION 
1. Rx A   
 
2. Rx B   
 
N/C 
3. Rx C   
 
N/C 
4. Rx D   
 
N/C 
5. Tx A   
 
6. Tx A   
 
7. Tx A   
 
8. Tx A   
 
1  
 
 
ESC. Exit 
 
             +------------------------+ 
             
|  Rx: From Network      
             
|  Tx: To Network        | 
             +------------------------+ 
 
Select item from the menu. 
Figure E-25.  Signaling Profile Configuration Parameters 
Table E-17.  Signaling Profile Configuration 
Parameter Possible 
Values 
Remarks 
Rx A 
A, A Inverse, N/C
 
Specifies which ABCD Signaling Bit (only one), and its polarity, 
carries the on hook/off hook information from the far-end device 
Rx B 
B, B Inverse, N/C 
Specifies which ABCD Signaling Bit (only one), and its polarity, 
carries the on hook/off hook information from the far-end device 
Rx C 
C, C Inverse, N/C 
Specifies which ABCD Signaling Bit (only one), and its polarity, 
carries the on hook/off hook information from the far-end device 
Rx D 
D, D Inverse, N/C
 
Specifies which ABCD Signaling Bit (only one), and its polarity, 
carries the on hook/off hook information from the far-end device 
Tx A 
A, A Inverse, 0, 1
 
Specifies which ABCD Signaling Bit carries the on hook/off hook 
information to the far-end device. One or more can be configured to 
carry the off-hook/on-hook information (or inverse information), 
while the other bits should be set to ‘1’ or ‘0’. 
Main Menu 
         ↓ 
2. Configuration 
         ↓  
2. Analog 
Configuration 
         ↓  
4. Signaling 
Profile 
Configuration 
        
 