Chapter 2  Installation 
IPmux-1/1E Installation and Operation Manual 
2-2  Installation and Setup
 
 
 
 
The DC power source must be isolated from the mains supply by double or 
reinforced insulation. A suitable fuse or a circuit breaker should be integrated in 
the negative power-supply line. 
 
 
Allow at least 90 cm (36 inches) of frontal clearance for operator access. Allow at 
least 10 cm (4 inches) clearance at the rear of the unit for cable connections. Make 
sure that the ventilation holes are not blocked. 
The ambient operating temperature of IPmux-1/1E is 0
o
 to 50
C (32
F to 122
F), 
at a relative humidity of up to 90%, non-condensing. 
2.3 Package Contents 
The IPmux-1/1E package contains the following items: 
•  IPmux-1/1E unit 
•  Power cord 
•  Kit containing hardware for mounting the unit in a 19-in rack (optionally 
supplied) 
−  RM-25 for IPmux-1 
−  RM-27 for IPmux-1E. 
Power Cable 
IPmux-1/1E comes equipped with the power cord connected to the AC/DC 
interface on the rear panel.  
2.4 Equipment Needed 
IPmux-1/1E needs no special tools for installation. A screwdriver is necessary when 
mounting IPmux-1/1E in a 19-in rack. 
2.5  Installation and Setup 
Setting Jumpers 
IPmux-1 
In general, IPmux-1 internal jumpers and switches do not need to be configured 
by the user. Therefore, removing the product cover is not required.  
Caution 