IPmux-1/1E Installation and Operation Manual 
Chapter 4  Troubleshooting and Diagnostics 
 
Diagnostic Tests 
4-5 
IPmux-1
ISDN S
 
Figure 4-4.  IPmux-1E/BRI Internal Loop 
➤ 
To run a loopback test: 
•  Press the <Spacebar> on your keyboard to toggle between the values:  
Internal/External /Disable
−  Internal:  Data received from the IP network side is looped back to the 
network transmit line.  
−  External:  Data received from the PBX at the receive ISDN S line is looped 
back to the ISDN S Tx path (toward the same PBX). Data coming from the 
IP network is ignored.  
−  Disable:  No loopback. Regular operation. 
Default value: Disable 
 
FXS 
Remote Loopback 
You can set a remote loopback analog signal, per port, in IPmux-1E with FXS 
interface. The analog signal is looped back towards the IP network.  
Tone Injection 
A 1 kHz tone, per port, is injected towards the local telephone set.   
➤ 
To run a test: 
•  Press the <Spacebar> on your keyboard to toggle between the values:  
Remote Loopback/Tone Injection/Disable
Default value: Disable
Main Menu 
↓ 
2. Configuration 
↓ 
2. ISDN 
Configuration 
↓ 
3. Channel 
Configuration 
↓ 
1. Choose 
Channel 
↓ 
3. Loopback 
State 
Main Menu 
↓ 
2. Configuration 
↓ 
2. ISDN 
Configuration 
↓ 
3. Channel 
Configuration 
↓ 
1. Choose 
Channel 
↓ 
5. Testing 