SuperTrak66™ User's Manual 
Chapter 3 
 
- 18 - 
Status 
Shows one of three possible array status conditions: 
 
 
Functional 
The array is fully operational, and no problems are present. 
 
Critical 
The array is operational, but has lost its fault tolerance. For RAID 
array levels 1, 3 and, 5 the array contains a failed drive. The user 
should identify and replace the failed drive.  
 
 
Offline 
The array is no longer operational and the SuperBuild utility cannot 
rebuild the array. The array must be rebuilt from the last tape 
backup or other device. The user should identify and replace the 
failed drives. For RAID levels 1, 3, and 5, at least two or more 
drives in the array have failed. For a RAID 0 array, at least one 
drive has failed.  
 
Main Menu 
 
Figure 6: SuperBuild Array Utility Main Menu 
 
Note: This menu uses number keys 1 through 5 to select options. Many of the 
subsequent menu windows use: arrow-pad keys to highlight options. Use the 
spacebar to cycle through choices for the selected option. Enter (return) to select 
a highlighted option. Escape to exit the menu.