SuperTrak66™ User's Manual 
Chapter 4 
 
- 33 - 
A typical installation of the SuperCheck software components on a network might 
look like Figure 17 on page  32.  The major elements of this network are (from top to 
bottom): 
 
− 
Remote Monitoring Stations (via Internet) 
− 
Main Network File Server (with direct Internet access via a Firewall) 
− 
Internal SuperTrak stations (connected via Intranet/LAN) 
− 
Internal Monitoring Station 
 
As shown, different components of SuperCheck are installed on each of the 
network elements.  
 
(1)  SuperCheck Utility - The SuperCheck Monitoring Utility (the GUI that you will 
be using) may be installed on any system element with a TCP/IP connection 
where you want to perform monitoring. As shown in Figure 17, the SuperCheck 
utility is installed on the main File Server, on both SuperTrak66 stations, on 
two remote systems over the Internet, and on one internal system. NOTE: For 
security reasons, array maintenance features can only be performed at the 
actual server location of a SuperTrak66 array and are unavailable at all other 
consoles.
 
 
(2)  Message Server  - The Message Server software component serves as the 
main link between all SuperTrak arrays residing on the network, the internal 
Intranet/LAN (via TCP/IP protocols), and remote monitoring stations 
communicating via the Internet. For remote Internet monitoring, the Message 
Server component must be installed on a machine with an unique IP address 
that is visible to the Internet (as in our example). From its cent ral 
communications position, the Message Server software interfaces with all 
SuperTrak arrays located on the LAN and allows all system elements (with the 
GUI installed) to see those arrays. The File Server where the Message Server 
software is installed may or may not house a SuperTrak array. In our example 
on  Figure  17, it does not. One reason may be that the File Server is not 
running Windows NT 4.0.  
 
(3)  Message Agent - The Message Agent software component must be installed 
on each file server that will house a SuperTrak array. The Message Agent 
communicates with both the Message Server and the SuperTrak66 controller. 
Installing the Message Agent automatically installs the I
2
O device driver. NOTE: 
All stations containing SuperTrak66 must be running Windows NT 4.0. 
Maintenance on SuperTrak arrays can be performed only using these stations 
.  
 
(4)  I
2
O Device Driver – Installed automatically with the Message Agent, the driver 
allows the station to communicate directly between the Promise SuperTrak 
controller card and Windows NT. This permits Windows NT to recognize RAID 
arrays attached to it.