R0E530640MCU00 User’s Manual 
5. Debugging Functions 
REJ10J1733-0100  Rev.1.00  Apr. 01, 2008 
Page 126 of 229 
 
 
 
 
5. Repeat fill until full
 
Each time a trace point is encountered, a total of 512 cycles before and after that point are acquired, and acquisition 
continues that way. When the trace memory overflows, acquisition is halted. The positions where trace points are 
encountered can be checked in the Trace window. 
 
Table 5.19 Specifiable conditions: Repeat fill until full 
Trace point setting 
Delay specification 
Capture/Do not Capture 
condition setting 
Step execution recording 
Possible - 
 
CAUTION 
If trace points are encountered in consecutive cycles in the repeat fill until stop or repeat fill until full mode, only one first 
cycle is highlighted in yellow as a trace point. 
 
5.9.5  Setting Trace Points 
(1) Setting trace points 
For trace points, you can set an OR condition, other condition (AND (Accumulation), AND (Simultaneous), subroutine, 
sequential or state transition) and detection of exception events. 
The OR condition, other condition and the detection of exception events can be set all at the same time, or only one at a time. 
 
 
 
 
 
Trace acquisition 
 
 
 
 
 
 
OR condition 
->
 
 
 
 
 
 
Other conditions 
 
 
 
 
AND (Accumulation) 
 
 
 
 
AND (Simultaneous) 
->
Trace point encountered 
 
 
Subroutine 
 
 
 
 
Sequential 
 
 
 
 
State transitions 
 
 
 
 
 
 
 
Exception event 
->
 
 
 
 
 
↓ 
} Delay value 
 
 
 
Trace acquisition halted 
 
Figure 5.50 Outline of the trace point