R0E530640MCU00 User’s Manual 
5. Debugging Functions 
REJ10J1733-0100  Rev.1.00  Apr. 01, 2008 
Page 143 of 229 
 
 
 
 
The contents displayed in this window are listed below. 
 
Table 5.23 Columns and contents 
Column Description 
No 
Numbers assigned to 1–8 measurement sections set in the Performance Analysis Conditions 
dialog box. 
Click Settings on the context menu to open the Performance Analysis Conditions dialog 
box. 
Condition 
Indicated as 
Enable
 when measurement conditions are set in the Performance Analysis 
Conditions dialog box. 
Otherwise, indicated as 
Disable
Run time 
(h:m:s.ms.us.ns) 
Cumulative execution time. It shows a cumulative time of measured execution time. 
Count 
Shows the number of times measured. 
Statistic 
Shows a ratio of cumulative execution time relative to Go–Break execution time. 
[Ratio calculation formula] 
(Cumulative execution time / Go–Break cumulative execution time) * 100 
Max (h:m:s.ms.us.ns) 
Maximum execution time per measurement performed 
Min (h:m:s.ms.us.ns) 
Minimum execution time per measurement performed 
Average (h:m:s.ms.us.ns) 
Average execution time per measurement performed 
 
 
 
5.10.3  Setting Performance Measurement Conditions 
In the Performance window, select a line of the section No. in which you want to set conditions and choose Set from the 
context menu. The Performance Analysis Conditions dialog box will be displayed. 
 
Figure 5.67 Performance Analysis Conditions dialog box