Справочник Пользователя для Renesas R0E530640MCU00

Скачать
Страница из 229
R0E530640MCU00 User’s Manual 
5. Debugging Functions 
REJ10J1733-0100  Rev.1.00  Apr. 01, 2008 
Page 146 of 229 
 
 
 
 
5.10.5  Clearing Performance Measurement Conditions 
Select the measurement condition you want to clear in the Performance Analysis window and then choose Set from the context 
menu to display the Performance Analysis Conditions dialog box. In the Performance Analysis Conditions dialog box, disable 
the condition you want to clear. 
 
Figure 5.71 Performance Analysis Conditions dialog box 
 
 
5.10.6  Clearing the Performance Measurement Result 
Select the section you want to clear in the Performance Analysis window and then choose Clear Data from the context menu. 
The measurement result of the selected section will be cleared. To clear all measurement results, choose Clear All Data from 
the context menu. 
 
 
5.10.7  About the Maximum Measurement Time of Performance 
(1) Maximum measurement time 
The timer used for performance measurement is comprised of a 40-bit counter.   
The maximum measurement time varies with the unit of measurement selected. 
To select the unit of measurement, use the Measurement Unit list box of the Performance Analysis Conditions dialog box. 
The measurable maximum times are listed in the table below. 
 
Table 5.26 Measurable maximum time 
No. 
Resolution 
Measurable maximum time 
10ns 
Approx. 3 hours, 03 minutes, 15 seconds 
20ns 
Approx. 6 hours, 06 minutes, 30 seconds 
40ns 
Approx. 12 hours, 13 minutes, 00 seconds 
80ns 
Approx. 24 hours, 26 minutes, 00 seconds 
160ns 
Approx. 48 hours, 52 minutes, 01 seconds 
6 1.6μs 
Approx. 488 hours, 40 minutes, 18 seconds 
 
CAUTION 
Note that performance measurement produces an error equal to 
±1 resolution (when resolution = 20 ns, ±20 ns). 
 
(2) Maximum measurement count 
Execution counts are measured using a 32-bit counter. Measurement can be taken of up to a count of 4,294,967,295.