R0E530640MCU00 User’s Manual 
5. Debugging Functions 
REJ10J1733-0100  Rev.1.00  Apr. 01, 2008 
Page 189 of 229 
 
 
 
 
5.13.4  Setting Function Profile Measurement Ranges 
Choose Set Ranges from the context menu that is displayed when you right-click in the present window. 
The Realtime Profile Setting dialog box will be displayed. In this dialog box, set a profile measurement range. 
 
[Function mode] 
 
Figure 5.131 Realtime Profile Setting dialog box 
 
 
(1) Memory allocation 
Before function profiles can be measured, profile memory must be allocated to the addresses at which to be measured. Profile 
data can be obtained from only the address range that has had memory allocated. 
The emulator permits any of 1–8 blocks (maximum 1 Mbyte) each beginning with the 128-Kbyte boundary to be specified as a 
profile measurement area. 
Contiguous blocks or noncontiguous blocks, either one, can be set. 
With initial settings, the profile memory is allocated to addresses in the ROM and RAM areas. 
 
(2) Automatic function detection 
When profile memory is allocated to addresses, the E100 emulator automatically detects functions included that address range 
and registers those functions in the window.