6. Troubleshooting (Action on Error) 
REJ10J1733-0100  Rev.1.00  Apr. 01, 2008 
Page 213 of 229 
 
 
 
 
6.3 Error at Debugger Startup 
 
(1) When the LEDs of the E100 Do Not Display Normally 
 
Table 6.1 Checkpoints of errors when the LEDs do not display normally 
Error 
Connection to 
the user system 
Checkpoint 
SAFE LED remains lit. 
Check that the power cable is connected. 
See "2.4 Connecting the Host Machine" (page 26)
 
 
SAFE LED does not light up. 
Recheck the connection between the E100 and this product. 
See “2.3 Connecting/Disconnecting the MCU Unit to/from the E100 
Emulator Main Unit
” (page 25). 
 
Target Status POWER LED 
does not light up. 
 
Connected 
Check that power (Vcc and GND) is properly supplied to the user 
system and that the user system is properly grounded. 
 
Target Status RESET LED does 
not go out. 
 
Connected (1)  Check that the reset pin of the user system is pulled up. 
(2)  When using the emulator without the user system, check to see 
if a converter board is disconnected from the emulator.