2.8 Selecting Clock Supply 
2.8.1 Clocks 
You can choose a clock supplied to the evaluation MCU by the Emulator tab in the Configuration properties dialog box of the 
emulator debugger. Table 2.1 shows the clocks and their initial settings. 
 
Table 2.1 Clock supply to the MCU 
Clock 
Display of 
emulator debugger 
Description Default 
setting 
Emulator 
IC17 mounting oscillator module 
Yes 
User 
Oscillator circuit on the user system 
Main (X
IN
-X
OUT
Generate 
Internal generator circuit 
(1.0--20.0 MHz) 
Emulator 
Internal oscillator circuit 
(32.768 kHz) 
Yes 
Sub (X
CIN
-X
COUT
User 
Oscillator circuit on the user system 
 
 
IMPORTANT 
Notes on Changing the Clock Supply: 
 
z
 The clock supply can be set by the Configuration properties dialog box when starting up the emulator debugger 
or inputting emulator_clock command on the Command Line window.