5.1.2  Setting Up the Target MCU 
(1) Selecting the target MCU 
On the Device page of the Device setting dialog box, specify the target MCU to be emulated. For details, refer to the hardware 
manual supplied with each product. 
 
Figure 5.1 Device setting dialog box (Device page) 
 
 
The target MCU you have set here cannot be changed after the emulator is connected. To change the target MCU, you need to 
disconnect the emulator and connect it again. 
 
(2) Selecting an operation mode 
Select one from the following options: 
Single-Chip mode, Memory expansion mode, Microprocessor mode 
 
CAUTION 
Options are different depending on the target MCU that you select. 
 
(3) Selecting an external data bus width 
You can set this when the operation mode you have selected is Memory expansion mode or Microprocessor mode. 
Select one from the following options: 
8 bits, 16 bits (initial value)