(2) Errors Occur When Starting Up the Emulator Debugger
(When the target system is connected)
Table 6.2 Checkpoints of errors when starting up the emulator debugger (target is connected)
Error
Communication ERROR.
Can't send data.
Target system is not constructed properly.
The version of M3T-PD30 and the firmware
on the target system are not same.
Target MCU is reset state.
Target MCU cannot be reset.
Target MCU is in HOLD state.
Target MCU is not given clock.
Target MCU is not given power.
Checkpoint
Check that all emulator debugger settings, interface
cable connections and switches on the rear of the PC4701
match.
See the user's manuals of the PC4701 and emulator
debugger.
(1) Download the proper firmware.
See the user's manual of the emulator debugger.
(2) Recheck that the connection between the PC4701
and this product.
See "3.4 Connecting the PC4701 and Emulation
Pod" (page 27).
(1) Download the proper firmware.
See "4.2 Downloading Firmware" (page 34).
(2) Check that the descriptions in the MCU file are
correct.
See "2.4 (1) Making the MCU File" (page 18).
Check that the reset pin of the target system has changed
from "L" to "H" level.
(1) Check that pin RESET* is "H" level.
(2) If the reset circuit of the target system has a watchdog
timer, disable the timer.
(3) Check that power is properly supplied to the target
system and that the target system is properly grounded.
(4) The program may be uncontrollable in areas where
memory is not allocated. Recheck that the map setting.
See "1.1 Notes on MAP References and Settings"
(page 11).
(1) The MCU is either in the stop mode or wait mode.
Either reset the MCU or cancel the mode with an
interrupt.
See MCU specifications.
(2) The program may be uncontrollable in areas where
memory is not allocated. Recheck that the map setting.
See "1.1 Notes on MAP References and Settings"
(page 11).
(1) Check that the oscillation circuit in the target system
is oscillating properly.
(2) Check that the switches of the FLX64-PRB are
correctly set.
See the user's manual of pod probe.
Check that power is properly supplied to the target
system and that the target system is properly grounded.