EM78M611E
 
Universal Serial Bus Series Microcontroller
 
 
Product Specification
 
(V1.11) 04.20.2007
 
 
 
•••• 15 
(This specification is subject to change without further notice)
 
 
8.2.2.12  RD (USB Application FIFO Address Register)   
Default Value: (0B_0000_0000) 
Bit 7  Bit 6  Bit 5 
Bit 4 
Bit 3 
Bit 2 
Bit 1 
Bit 0 
UAD4 
UAD3 
UAD2 
UAD1 
UAD0 
RD [0~4]  USB Application FIFO address registers.  These five bits are the address 
pointers of USB Application FIFO.  
RD [5~7]    Undefined registers. The default value is zero.  
8.2.2.13  RE (USB Application FIFO Data Register)   
Default Value: (0B_0000_0000) 
Bit 7 
Bit 6 
Bit 5 
Bit 4 
Bit 3 
Bit 2 
Bit 1 
Bit 0 
UD7 
UD6 
UD5 
UD4 
UD3 
UD2 
UD1 
UD0 
RE  (USB  Application  FIFO  data  register)  contains  the  data  in  the  register  of  which 
address is pointed by RD.  
NOTE 
For example, if user wants to read the fourth byte of EndPoint Zero, user has to use the 
address of EP0 (0x00) and Data  Byte Pointer of EP0 (0x10) to access it.  
// Read the 4th byte of the EP0 FIFO 
// First, assign the data byte pointer of EP0 register (0X10) with 0X03.    
MOV  A, @0X10 
MOV RD, a          // Move data in A to RD register  
MOV  A, @0X03 
MOV RE , A               // Move data in A to RE register 
 
// Then read the content from EP0 FIFO (0x00) 4th byte 
MOV  A, @0X00 
MOV RD, A        // Assign address point to EP0 FIFO 
MOV A, RE        // Read the fourth byte data (Byte 3) of the EP0 FIFO 
MOV  A, 0X0E // Read the fifth byte data (Byte 4) of the EP0 FIFO
 
8.2.2.14  RF (Interrupt Status Register)  Default Value: (0B_0000_0000) 
Bit 7 
Bit 6 
Bit 5 
Bit 4 
Bit 3 
Bit 2 
Bit 1 
Bit 0 
USB Host 
Resume_IF 
SE2_IF 
SE1_IF 
Port7 state 
change_1F 
USB 
Reset_IF 
USB 
Suspend_IF 
EP0_IF 
TCC_IF 
RF [0]  TCC Overflow interrupt flag.  It will be set while TCC overflows, and is cleared 
by firmware.  
RF [1]  EndPoint Zero interrupt flag.  It will be set when the EM78M611E receives 
Vendor/Customer Command to EndPoint Zero.  This bit is cleared by 
firmware.