Справочник Пользователя для IBM DS4000 FC

Скачать
Страница из 84
Installing
 
the
 
FC
 
4Gbps
 
PCI-X
 
Adapter
 
Attention:
  
To
 
avoid
 
damage
 
to
 
your
 
fiber-optic
 
cables,
 
follow
 
these
 
guidelines:
 
v
   
Do
 
not
 
route
 
the
 
cable
 
along
 
a
 
folding
 
cable-management
 
arm.
 
v
    
For
 
devices
 
on
 
slide
 
rails,
 
leave
 
enough
 
slack
 
in
 
the
 
cables
 
so
 
that
 
they
 
do
 
not
 
bend
 
to
 
a
 
diameter
 
of
 
less
 
than
 
76
 
mm
 
(3
 
in.)
 
or
 
to
 
a
 
radius
 
less
 
than
 
38
 
mm
 
(1.5
 
in.)
 
when
 
extended
 
or
 
become
 
pinched
 
when
 
retracted.
 
v
   
Route
 
the
 
cable
 
away
 
from
 
places
 
where
 
it
 
can
 
be
 
damaged
 
by
 
other
 
devices
 
in
 
the
 
rack
 
cabinet.
 
v
   
Do
 
not
 
use
 
plastic
 
cable
 
ties
 
in
 
place
 
of
 
the
 
provided
 
cable
 
straps.
 
v
   
Do
 
not
 
overtighten
 
the
 
cable
 
straps
 
or
 
bend
 
the
 
cables
 
to
 
a
 
diameter
 
of
 
less
 
than
 
76
 
mm
 
(3
 
in.)
 
or
 
a
 
radius
 
less
 
than
 
38
 
mm
 
(1.5
 
in.).
 
v
   
Do
 
not
 
put
 
excess
 
weight
 
on
 
the
 
cable
 
at
 
the
 
connection
 
point.
 
Be
 
sure
 
that
 
the
 
cable
 
is
 
well
 
supported.
 
v
   
The
 
following
 
are
 
the
 
recommended
 
maximum
 
cable
 
lengths.
 
   
1Gbps:
 
500
 
meters
 
50/125
 
µm
 
fiber,
 
300
 
meters
 
62.5/125
 
µm
 
fiber
 
   
2Gbps:
 
300
 
meters
 
50/125
 
µm
 
fiber,
 
150
 
meters
 
62.5/125
 
µm
 
fiber
 
   
4Gbps:
 
150
 
meters
 
50/125
 
µm
 
fiber,
 
70
 
meters
 
62.5/125
 
µm
 
fiber
  
 
CAUTION:
 
When
 
laser
 
products
 
(such
 
as
 
CD-ROMs,
 
DVD
 
drives,
 
fiber
 
optic
 
devices,
 
or
 
transmitters)
 
are
 
installed,
 
note
 
the
 
following:
 
v
   
Do
 
not
 
remove
 
the
 
covers.
 
Removing
 
the
 
covers
 
of
 
the
 
laser
 
product
 
could
 
result
 
in
 
exposure
 
to
 
hazardous
 
laser
 
radiation.
 
There
 
are
 
no
 
serviceable
 
parts
 
inside
 
the
 
device.
 
v
   
Use
 
of
 
controls
 
or
 
adjustments
 
or
 
performance
 
of
 
procedures
 
other
 
than
 
those
 
specified
 
herein
 
might
 
result
 
in
 
hazardous
 
radiation
 
exposure.
  
 
DANGER
Some
 
laser
 
products
 
contain
 
an
 
embedded
 
Class
 
3A
 
or
 
Class
 
3B
 
laser
 
diode.
 
Note
 
the
 
following.
 
Laser
 
radiation
 
when
 
open.
 
Do
 
not
 
stare
 
into
 
the
 
beam,
 
do
 
not
 
view
 
directly
 
with
 
optical
 
instruments,
 
and
 
avoid
 
direct
 
exposure
 
to
 
the
 
beam.
 
The
 
FC
 
4Gbps
 
PCI-X
 
Adapter
 
comes
 
with
 
an
 
attached
 
standard
 
3U
 
adapter
 
bracket
 
as
 
shown
 
in
 
 
An
 
additional
 
Low
 
Profile
 
2U
 
bracket
 
also
 
comes
 
with
 
the
 
adapter.
 
Before
 
you
 
install
 
the
 
FC
 
4Gbps
 
PCI-X
 
Adapter,
 
verify
 
whether
 
you
 
need
 
the
 
Fibre
 
Channel
 
Low
 
Profile
 
2U
 
adapter
 
bracket.
 
If
 
you
 
need
 
to
 
install
 
the
 
Low
 
Profile
 
2U
 
bracket,
 
continue
 
with
 
step
 
 
Otherwise,
 
go
 
to
 
step
 
 
 
1.
   
Complete
 
the
 
following
 
steps
 
to
 
install
 
the
 
Fibre
 
Channel
 
Low
 
Profile
 
2U
 
adapter
 
bracket:
 
 
6
 
IBM
 
System
 
Storage
 
DS4000
 
FC
 
4Gbps
 
PCI-X
 
Single/Dual
 
Port
 
HBA:
 
Installation
 