Справочник Пользователя для IBM DS4000 FC

Скачать
Страница из 84
Note:
  
Remember,
 
the
 
drive
 
letter
 
must
 
be
 
mapped
 
to
 
the
 
root
 
of
 
the
 
NetWare
 
SYS
 
volume.
 
5.
   
When
 
you
 
are
 
prompted
 
to
 
enable
 
the
 
QLogic
 
failover
 
configuration,
 
do
 
not
 
enable
 
it.
 
(IBM
 
recommends
 
the
 
use
 
of
 
the
 
RDAC
 
multipath
 
driver
 
as
 
the
 
DS4000
 
LUN
 
failover/failback
 
driver,
 
in
 
a
 
Microsoft
 
Windows
 
environment
 
or
 
the
 
Novell
 
NetWare
 
native
 
multipath
 
device
 
driver
 
in
 
a
 
NetWare
 
environment.)
 
The
 
following
 
are
 
known
 
limitations.
 
v
   
The
 
DS4000
 
storage
 
products
 
do
 
not
 
support
 
the
 
use
 
of
 
SANSurfer
 
to
 
configure
 
failover
 
and
 
failback
 
paths
 
or
 
IO
 
load
 
balancing
 
for
 
the
 
DS4000
 
storage
 
subsystem
 
logical
 
drives
 
(LUNs)
 
using
 
the
 
QLogic
 
failover
 
version
 
(QLDirect)
 
of
 
the
 
FC
 
HBA
 
device
 
driver
 
in
 
Microsoft
 
Windows
 
environments.
 
IBM
 
only
 
supports
 
the
 
use
 
of
 
DS4000
 
RDAC
 
multipath
 
device
 
driver
 
in
 
conjunction
 
with
 
the
 
non-failover
 
version
 
of
 
the
 
QLogic
 
FC
 
HBA
 
device
 
driver.
 
v
   
The
 
DS4000
 
storage
 
products
 
do
 
not
 
support
 
the
 
use
 
of
 
LUN
 
masking
 
or
 
HBA
 
configuration
 
wizard/functions;
 
neither
 
do
 
the
 
DS4000
 
storage
 
products
 
support
 
non-Fibre
 
Channel
 
HBA
 
functions,
 
such
 
as
 
QLogic
 
SANSwitch
 
or
 
iSCSI
 
HBA
 
functions.
 
v
   
The
 
QLogic
 
SANSurfer
 
Pro
 
Utility
 
program
 
(formerly
 
known
 
as
 
IBM
 
FAStT
 
MSJ
 
program)
 
must
 
not
 
be
 
left
 
installed
 
on
 
X64
 
servers
 
with
 
Microsoft
 
Windows
 
Server
 
2003
 
64-Bit
 
edition,
 
while
 
the
 
servers
 
are
 
running
 
IOs
 
to
 
DS4000
 
storage
 
subsystems.
 
Install
 
the
 
QLogic
 
SANSurfer
®
 
Pro
 
Utility
 
program
 
if
 
you
 
need
 
to
 
perform
 
FC
 
HBA
 
updates
 
or
 
diagnostics;
 
then,
 
uninstall
 
it
 
immediately
 
after
 
you
 
have
 
completed
 
these
 
tasks.
 
v
   
There
 
is
 
no
 
64-Bit
 
version
 
of
 
the
 
QLogic
 
SANSurfer
 
Pro
 
Utility
 
program
 
(formerly
 
known
 
as
 
FAStT
 
MSJ)
 
for
 
Windows
 
Server
 
2003
 
IA64
 
or
 
x64
 
editions.
 
You
 
must
 
use
 
the
 
32-Bit
 
version
 
of
 
the
 
QLogic
 
SANSurfer
 
Pro
 
Utility
 
program
 
for
 
the
 
Windows
 
Server
 
2003
 
64-Bit
 
edition.
 
Uninstall
 
the
 
QLogic
 
SANSurfer
 
Pro
 
Utility
 
program
 
when
 
the
 
diagnostics
 
are
 
complete;
 
otherwise,
 
the
 
program
 
could
 
cause
 
the
 
server
 
to
 
crash
 
in
 
heavy
 
IO
 
loads.
Note:
  
For
 
information
 
about
 
other
 
possible
 
program
 
limitations,
 
please
 
see
 
the
 
README
 
file.
If
 
you
 
have
 
questions
 
about
 
installing
 
the
 
QLogic
 
SANsurfer
 
Pro
 
Utility,
 
please
 
see
 
the
 
README
 
file,
 
which
 
may
 
have
 
a
 
name,
 
for
 
example,
 
like
 
readme_SANsurfer_FAStMSJ_win32_NW.txt.
 
Installing
 
on
 
the
 
Linux
 
platform
 
Note:
  
If
 
SANSurfer
 
is
 
already
 
installed,
 
uninstall
 
it
 
prior
 
to
 
installing
 
a
 
new
 
copy.
 
GUI
 
installation
 
To
 
perform
 
the
 
SANSurfer
 
Pro
 
Utility
 
installation
 
on
 
a
 
Linux
 
platform,
 
you
 
must
 
execute
 
four
 
steps.
 
1.
   
Open
 
a
 
shell
 
(command
 
prompt),
 
and
 
change
 
to
 
the
 
directory
 
that
 
contains
 
the
 
installation
 
file,
 
which
 
might
 
for
 
example,
 
be
 
named
 
sansurfer2.0.30b62_linux_install-i.bin.
 
2.
   
At
 
the
 
prompt,
 
type
 
the
 
command
 
to
 
start
 
the
 
program
 
installation
 
wizard.
 
sh
 
./program_name
 
where,
 
program_name
 
is
 
sansurfer2.0.30b62_linux_install-i.bin
 
 
Chapter
 
2.
 
Installing
 
the
 
FC
 
4Gbps
 
PCI-X
 
Adapter
 
device
 
drivers
 
and
 
updating
 
the
 
BIOS
 
code
 
11